Showing 1–12 of 17 results

Show sidebar

HYDROCAL 1001+

Cost effective and comprehensive monitoring of 6 fault gases · Measurement of Moisture (H2O) in the transformer oil · Easy and fast installation while the transformer is operating · Compact and resistant design for long lasting usage · ETHERNET and CAN bus interfaces to support proprietary communication protocols and to be open / prepared for substation communication protocols MODBUS®TCP, CANopen The Hydrocal 1001+ is a permanently installed composite gas in oil sensor for the Total Dissolved Combustible Gases (TDCG) analysis of the key fault gases Hydrogen (H2), Carbon Monoxide (CO), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4) and Ethane (C2H6). To detect an even wider range of potential transformer faults, the Hydrocal 1001+ analyses additionally the content of Moisture (H2O) in the transformer oil. The Hydrocal 1001+ is a fully integrated (6 key fault gases and Moisture in oil) compact and cost effective device used in particular for early transformer fault detection and preventative maintenance. Click for the Leaflet

HYDROCAL 1003

Maintenance free system · Easy to mount on the operating transformer without any operational interruption · ETHERNET (Option), RS 232 and RS 485 interfaces to support MODBUS® RTU/ASCII, DNP3 and proprietary communication protocols and to be open / prepared for substation communication protocol IEC 61850 · Option: Offshore version The Hydrocal 1003 is an online transformer monitoring device for the dissolved gas analysis (DGA) of the key fault gases Hydrogen (H2) and Carbon Monoxide (CO). In addition, water contamination deteriorates the performance of the oil as high moisture content increases the risk of corrosion and overheating. The Hydrocal 1003 reacts on this issue and provides its users the analysis of Moisture (H2O) in the transformer oil to achieve an even higher safety standard Click for the Leaflet

HYDROCAL 1003 OFFSHORE

Individual analysis of the dissolved gas contents hydrogen (H2) and carbon monoxide (CO) Analysis of moisture (H2O) dissolved in transformer oil (both, relative humidity [%] and absolute humidity [ppm]) Special design for Offshore Wind Power Applications: Housing without window painted C5M Back plate with 2 cable glands M20 (chrome-nickel steel, IP 55, corrosion-free and acid-resistant). Optional with 4 cable glands (2x M20 and 2 x M25). Back plate, oil entrance and housing screws made of stain-less steel V4A Easy to mount on a transformer valve (G 1½" DIN ISO 228-1 or 1½" NPT ANSI B 1.20.1) Installation on the operational transformer without any opera-tional interruption Advanced software (on the unit and via PC) Maintenance free system Communication interfaces ETHERNET (Option) 10/100 Mbit/s (copper-wired / RJ45 or fibre-optical / SC duplex), RS 232 and RS 485 to support MODBUS® RTU/ASCII, DNP3 and proprie-tary communication protocols and to be open / prepared for substation communication protocol IEC 61850 Optional GSM- or analog modem for remote access Optional DNP3 serial modem for SCADA connection Click for the Leaflet

HYDROCAL 1004 genX

Individual measurement of Hydrogen (H2), Carbon Monoxide (CO) and Acetylene (C2H2) Moisture in Oil (H2O) measurement Easy to mount on a transformer valve (G 1½" DIN ISO 228-1 or 1½" NPT ANSI B 1.20.1) Easy to mount on the operating transformer without any operational interruption Maintenance free system due to less movable parts Advanced software (on the unit and via PC) with intuitive operation by 7” color TFT capacitive touchscreen, WLAN and Webserver operation from any smart phone, tablet or notebook Communication interfaces ETHERNET 10/100 Mbit/s (copperwired / RJ 45 or fibre-optical / SC Duplex) and RS 485 to support MODBUS® RTU/ASCII, MODBUS TCP, DNP3,proprietary communication protocols and substation communication protocol IEC 61850 Optional external I/O module Click for the Leaflet

HYDROCAL 1005

Maintenance free system Easy to mount on the operating transformer without any operational interruption · ETHERNET and RS 485 interfaces to support MODBUS®RTU/ ASCII, MODBUS®TCP, DNP3 and proprietary communication protocols and to be open / prepared for substation communication protocol IEC 61850 · Option: Offshore version The Hydrocal 1005 is a permanently installed multi gas in oil analysis system with transformer monitoring functions. It individually measures Moisture in oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Acetylene (C2H2) and Ethylene (C2H4) dissolved in the transformer oil. Especially the presence and increase of Acetylene (C2H2) and Ethylene (C2H4) further classifies the nature of a fault as overheating, partial discharge or high energy arcing. The Hydrocal 1005 offers as a compact transformer monitoring system by the integration of other sensors present on a transformer (TCU Transformer Control Unit and / or bushing monitoring). Click for the Leaflet

HYDROCAL 1005 -3/-2/-1

· Cost efficient monitoring of up to three transformer tanks with one Hydrocal 1005-3/-2/-1 · ETHERNET and RS 485 interfaces to support MODBUS®TCP, DNP3 and proprietary communication protocols and to be open / prepared for substation communication protocol IEC 61850 The Hydrocal 1005-3/-2/-1 is a multi gas in oil analysis system for the monitoring of a bank of up to three single phase transformers located close to each other. The wall mounted system individually measures Moisture in oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Acetylene (C2H2) and Ethylene (C2H4) dissolved in the transformer oil utilising a smart sampling system that samples oil from each tank via three separate oil channels. It furthermore serves as a compact transformer monitoring system by the integration of other sensors present on a transformer. Click for the Leaflet

HYDROCAL 1005 OFFSHORE

Individual measurement of Hydrogen (H2), Carbon Monoxide (CO), Acetylene (C2H2) and Ethylene (C2H4) Moisture in oil (H2O) measurement Special design for offshore applications: Housing without window painted in C5M Back plate with cable glands (chrome-nickel steel, IP 68, corrosion-free and acid-resistant) Back plate, oil entrance and housing screws made of stain-less steel V4A Easy to mount on a transformer valve (G 1½" DIN ISO 228-1 or 1½" NPT ANSI B 1.20.1) Installation on the operational transformer without any operational interruption Advanced software (on the unit and via PC) Maintenance free system Communication interfaces ETHERNET 10/100 Mbit/s (copper-wired /RJ 45 or fibre-optical / SC Duplex) and RS 485 to support MODBUS®RTU/ASCII, MODBUSTCP, DNP3 proprietary communication and IEC 61850 protocols Optional on-board GSM or analog modem for remote access Optional DNP3 serial modem for SCADA connection Optional IEC 61850 modem for SCADA connection Click for the Leaflet

HYDROCAL 1006 genX

Individual measurement of Hydrogen (H2), Carbon Monoxide (CO), Acetylene (C2H2), Methane (CH4) and Ethylene (C2H4) Moisture in Oil (H2O) measurement Easy to mount on a transformer valve (G 1½" DIN ISO 228-1 or 1½" NPT ANSI B 1.20.1) Easy to mount on the operating transformer without any operational interruption Maintenance free system due to less movable parts Advanced software (on the unit and via PC) with intuitive operation by 7” color TFT capacitive touchscreen, WLAN and Webserver operation from any smart phone, tablet or notebook PC Communication interfaces ETHERNET 10/100 Mbit/s (copperwired / RJ 45 or fibre-optical / SC Duplex) and RS 485 to support MODBUS® RTU/ASCII, MODBUSTCP, DNP3, proprietary communication protocols and substation communication protocol IEC 61850 Optional external I/O module Click for the Leaflet

HYDROCAL 1008

Product Information Maintenance free system · Easy to mount on the operating transformer without any operational interruption · ETHERNET and RS 485 interfaces to support MODBUS®RTU/ASCII, MODBUS®TCP, DNP3 and proprietary communication protocols and to be open / prepared for substation communication protocol IEC 61850 · Option: Offshore version The Hydrocal 1008 is a permanently installed multi-gas-in-oil analysis system with transformer monitoring functions. It individually measures Moisture in oil (H2O) and the key gases Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO) Methane (CH4), Acetylene (C2H2), Ethylene (C2H4) and Ethane (C2H6) dissolved in the transformer oil. With the accurate analysis of 7 fault gases plus Moisture in oil, the Hydrocal 1008 is MTE ́s most comprehensive transformer monitoring system, which can be even expanded with different extension packages TCU Transformer Control Unit and / or Bushing Monitoring. Click for the Leaflet

HYDROCAL 1008 OFFSHORE

Individual measurement of Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4) and Ethane (C2H6) Moisture in oil (H2O) measurement Special design for offshore applications: Housing without window painted in C5M Back plate with cable glands (chrome-nickel steel, IP 68,corrosion-free and acid-resistant) Back plate, oil entrance and housing screws made of stainless steel V4A Easy to mount on a transformer valve (G 1½" DIN ISO 228-1 or 1½" NPT ANSI B 1.20.1) Installation on the operational transformer without any operational interruption Advanced software (on the unit and via PC) Maintenance free system Communication interfaces ETHERNET 10/100 Mbit/s (copperwired / RJ 45 or fibre-optical / SC Duplex) and RS 485 to support MODBUS®RTU/ASCII, MODBUSTCP, DNP3 proprietary communication and IEC 61850 protocols • Optional on-board GSM or analog modem for remote access • Optional DNP3 serial modem for SCADA connection • Optional IEC 61850 modem for SCADA connection • Optional HV and LV bushing sensors for HV and LV bushing monitoring applications via communication interface Click for the Leaflet

HYDROCAL 1009

Product Information Multi-Gas-in-Oil Analysis System with Transformer Monitoring Functions. The Hydrocal 1009 is a permanently installed multi-gas-in-oil analysis system with transformer monitoring functions.It individually measures, Moisture in Oil (H2O) and the key gases Hydrogen (H2),Carbon Monoxide (CO),Carbon Dioxide (CO2),Methane (CH4),Acetylene (C2H2),Ethylene (C2H4),Ethane (C2H6) and Oxygen (O2) dissolved in transformer oil. Key Advantages Individual measurement of Hydrogen (H2), Carbon Monoxide (CO),Carbon Dioxide (CO2),Methane (CH4),Acetylene (C2H2),Ethylene (C2H4),Ethane (C2H6) and Oxygen (O2) Moisture in Oil (H2O) measurement Easy to mount on a transformer valve Installation on the operational transformer without any operational interruption Advanced software (on the unit and via PC) Maintenance free system Communication interfaces ETHERNET 10/100 Mbit/s (copper-wired /RJ 45 or fibre-optical /SC Duplex) and RS 485 to support MODBUS ® RTU/ASCII, MODBUS®TCP,DNP3 proprietary communication and IEC 61850 protocols Optional on-board GSM or analog modem for remote access Optional DNP3 serial modem for SCADA connection Optional IEC 61850 modem for SCADA connection Optional HV and LV bushing sensors for HV and LV bushing monitoring applications via communication interface Click for the Leaflet

HYDROCAL 1009 OFFSHORE

Individual measurement of Hydrogen (H2), Carbon Monoxide (CO), Carbon Dioxide (CO2), Methane (CH4), Acetylene (C2H2), Ethylene (C2H4), Ethane (C2H6) and Oxygen (O2) Moisture in Oil (H2O) measurement Special design for offshore applications: Housing without window painted in C5M Back plate with cable glands (chrome-nickel steel, IP 68, corrosion-free and acid-resistant) Back plate, oil entrance and housing screws made of stainless steel V4A Easy to mount on a transformer valve (G 1½" DIN ISO 228-1 or 1½" NPT ANSI B 1.20.1) Installation on the operational transformer without any operational interruption Advanced software (on the unit and via PC) Maintenance free system Communication interfaces ETHERNET 10/100 Mbit/s (copperwired / RJ 45 or fibre-optical / SC Duplex) and RS 485 to support MODBUS®RTU/ASCII, MODBUS TCP, DNP3 proprietary communication and IEC 61850 protocols Optional on-board GSM or analog modem for remote access Optional DNP3 serial modem for SCADA connection Optional IEC 61850 modem for SCADA connection Optional HV and LV bushing sensors for HV and LV bushing monitoring applications via communication interface Click for the Leaflet