CheckSystem 2.1
Single-phase test system with class 0.2 reference standard and integrated single-phase current source up to 120 A.The CheckSystem 2.1 allows the monitoring of meter installations as well as analysis of the local mains conditions.
Advantages
Easy verification of meters under precise load conditions, using the built-in, compact, current source
Automatic operation using predefined load points without the need for an external PC
User-friendly system for data input and operation of source and reference meter
The system may be used either as a stand-alone reference standard meter, or together with the integrated power source
Functions
Independent generation of single-phase current loading conditions for verification of meters using the incoming supply voltage
Active, reactive and apparent energy measurement with integrated error calculator and pulse output
Voltage measurement
Current measurement directly or with clamp-on CT
Active, reactive and apparent power measurement
Phase angle, power factor and frequency measurement Options
Download Catalog
CheckSystem 2.1 S
Single-phase test system with class 0.05 reference standard and integrated single-phase current source up to 120 A. The CheckSystem 2.1 S allows the monitoring of meter installations as well as analysis of the local mains conditions.
Advantages
Easy verification of meters under precise load conditions, using the built-in, compact, current source
Automatic operation using predefined load points without the need for an external PC
Internal memory for storage of measurement results and customer data
User-friendly system for data input and operation of source and reference meter
The system may be used either as a stand-alone reference standard meter, or together with the integrated power source
Functions
Independent generation of single-phase current loading conditions for verification of meters using the incoming supply voltage
Active, reactive and apparent energy measurement with integrated error calculator and pulse output
Voltage measurement
Current measurement directly or with clamp-on CT
Active, reactive and apparent power measurement
Phase angle, power factor and frequency measurement
Download the Catalog
CheckSystem 2.3
Three-phase test system with class 0.2 reference standard and integrated three-phase current source up to 16 A. The CheckSystem 2.3 allows the monitoring of meter installations as well as analysis of the local mains conditions.
Advantages
Easy verification of meters under precise load conditions, using the built-in, compact, current source
Automatic operation using predefined load points without the need for an external PC
Internal memory for storage of measurement results and customer data
User-friendly system for data input and operation of source and reference meter
The system may be used either as a stand-alone reference standard meter, or together with the integrated power source
Functions
Independent generation of single or three phase current loading conditions for verification of meters using the incoming supply voltage
Active, reactive and apparent energy measurement for three phase, 3- or 4-wire systems, with integrated error calculator and pulse output
Voltage measurement
Current measurement directly or with clip-on CT’s
Active, reactive and apparent power measurement
Phase angle, power factor and frequency measurement
Download Catalog
PTS 2.3 C
Three-phase, fully automatic test system with a class 0.1 reference standard and integrated three-phase current source. The PTS 2.3 C allows the monitoring of meter installations as well as analysis of the local mains conditions.
Advantages
Easy verification of meters under precise load conditions, using the built-in, compact, current source
Automatic operation with predefined load points without the need for an external PC
Exchangeable Compact Flash (CF) memory card for measurement results and customer data
User-friendly system for data input and operation of combined source and reference meter
The system may be used either as a stand-alone reference standard meter, or together with the integrated power source
Functions
Independent generation of single or three-phase current loading conditions for verification of meters using the incoming supply voltage
Active, reactive and apparent energy measurement for three phase, 3 or 4-wire, systems with integrated error calculator and pulse output
Burden measurement of Current Transformer (CT) and Potential Transformer (PT)
Ratio testing of Current Transformers (CT
Click for the Leaflet
PTS 2.3 genX
Advantages
• Easy verification of meters under precise load conditions, using the built-in, compact, current source
• Automatic operation with predefined load points without the need for an external PC
• Large 9” (800 x 480 pixels) TFT touch screen colour display with graphical user interface
• Data transfer and communication via USB (Type B), ETHERNET or WLAN
• Built in web server for remote display of graphical user interface and remote control of the unit
• Data storage on removable SD memory card
• Two USB (type A) connectors for connection of peripherals like mouse, keyboard
Functions
• Independent generation of single- or three-phase current loading conditions for verification of meters using the incoming supply voltage
• Active, reactive and apparent energy measurement for three phase, 3 or 4-wire, systems with integrated error calculator and pulse output
• Vector diagram, harmonics spectrum, wave form and rotary field display for analysis of the mains conditions
• Burden measurement of Current Transformer (CT) and Potential Transformer (PT)
• Ratio testing of Current Transformers (CT)
Options
• Software CALegration
• UCT 120.3 set of 3 clamp-on CT’s 120 A
• UCT 1000.3 set of 3 clamp-on CT’s 1000 A
• UCT LEM.3 set of 3 flexible current probes FLEX 3000 (30/300/3000A)
• UCT AMP-LiteWire 3-phase adapter set for AmpLiteWire
+ primary high voltage current sensor AmpLiteWire 2000 A
Click for the Leaflet
PTS 3.1 C
Single-phase test system with class 0.1 reference standard and integrated single-phase current and voltage source. The PTS 3.1 C allows the monitoring of meter installations as well as analysis of the local mains conditions.
Advantages
Easy verification of meters under precise load conditions, using the built-in, compact, current and voltage source
Automatic operation with predefined load points without the need for an external PC
Exchangeable Compact Flash (CF) memory card for measurement results and customer data
User-friendly system for data input and operation of combined source and reference meter
Functions
Independent generation of single-phase loading conditions for verification of meters
Active, reactive and apparent energy measurement for single phase 2-wire systems with integrated error calculator and pulse output
Burden measurement of Current Transformer (CT) and Potential Transformer (PT)
Ratio testing of Current Transformers (CT)
Download Catalog
PTS 3.3 C
Three-phase, fully automatic test system with class 0.05 reference standard and integrated three-phase current and voltage source. The PTS 3.3 C allows the monitoring of meter installations as well as analysis of the local mains conditions.
Advantages
Easy verification of meters under precise load conditions, using the built-in, compact, current and voltage source
Automatic operation with predefined load points without the need for an external PC
Exchangeable Compact Flash (CF) memory card for measurement results and customer data
The system may be used either as a stand-alone reference standard meter, or together with the integrated power sourc
Functions
Independent generation of single or three-phase loading conditions for verification of meters
Active, reactive and apparent energy measurement for three phase, 3 or 4-wire, systems with integrated error calculator and pulse output
Burden measurement of Current Transformer (CT) and Potential Transformer (PT)
Click for the Leaflet
PTS 3.3 genX
The PTS 3.3 genX portable test system consists of an integrated three-phase current and voltage source unit and a three-phase electronic reference standard of accuracy class 0.05. Characteristic features of the PTS 3.3 genX are its wide measuring range, high accuracy and high tolerance to unwanted external influences.The PTS 3.3 genX allows the monitoring of meter installations as well as analysis of the local mains conditions.
Advantages
• Easy verification of meters under precise load conditions, using the built-in, compact, current and voltage source
• Automatic operation with predefined load points without the need for an external PC
• Large 9” (800 x 480 pixels) TFT touch screen colour display with graphical user interface
• Data transfer and communication via USB (Type B), ETHERNET or WLAN
• Built in web server for remote display of graphical user interface and remote control of the unit
• Data storage on removable SD memory card
• Two USB (type A) connectors for connection of peripherals like mouse, keyboard
Functions
• Independent generation of single- or three-phase loading conditions for verification of meters
• Active, reactive and apparent energy measurement for three phase, 3 or 4-wire, systems with integrated error calculator with 2 pulse inputs (1 configurable as output)
• Vector diagram, harmonics spectrum, wave form and rotary field display for analysis of the mains conditions
• Burden measurement of Current Transformer (CT) and Potential Transformer (PT)
• Ratio testing of Current Transformers (CT)
Click for the Leaflet
PTS 400.3+
Operation of the system
The PRS 600.3 is the operation interface for the
two system modules of the Portable Test System
PTS 400.3 PLUS and allows direct operation of
the reference standard and / or one of the available
portable power source modules PPS 400.3-
12A or PPS 400.3-120A.
The operation concept is based on touch screen
operation with self-explaining functional software
buttons.The operator can not only perform single test
steps but also easily predefine and store automatic
test runs using the sequence function and
advanced database functions of the system.
The overall functionality is comparable to modern
stationary meter test systems.
In case the touch operation is not possible (e.g. if
gloves must be worn for safety reasons at on-site
tests), the system can also be operated with the
integrated pen on the right side of the housing.
PTS 400.3 PLUS-12 A Three-phase portable test system
· Reference standard module PRS 600.3, accuracy class 0.02
· Current and voltage measurement up to 120 A and 520 V
· Current and voltage generation up to 12 A and 300 V
· Vector diagram, harmonic spectrum, wave form and rotary field
display, PQ measurement functions
· Burden measurement and ratio test of PTs and CTs
· Dimensions: W 510 x H 195 x D 480 mm
· Weight: approx. 26 kg
PTS 400.3 PLUS-120 A Three-phase portable test system
· Reference standard module PRS 600.3 accuracy class 0.02
· Current and voltage measurement up to 120 A and 520 V
· Current and voltage generation up to 120 A and 300 V
· Vector diagram, harmonic spectrum, wave form and rotary field
display, PQ measurement functions
· Burden measurement and ratio test of PTs and CTs
· Dimensions: W 510 x H 195 x D 480 mm
· Weight: approx. 29 kg
Download the Catalog