K2006
The K 2006 is a three phase comparator which has
been especially developed for universal laboratory
and test area use. It is intended for checking and
calibration of reference standard power and energy
meters, for calibration of precision current and voltage
sources and for verification of electrical standard
measurements and electricity meter test systems.
The unit uses analogue - digital converters (ADCs)
for its data acquisition, these being controlled and
read by a digital signal processor (DSP).
The comparator may be directly connected to an
external computer system over its RS 232 C serial
interface.
The comparator is distinguished by having very wide
measuring ranges for all AC values while still being
of accuracy class 0.01%:
Voltage: 30 V ... 500 V
Current: 50 mA ... 160 A.
In addition low currents from 1 mA are measured.
Range selection may be made either manually or
automatically.
The advanced conception of the K 2006 Comparator
is based on our considerable previous experience of
reference standard meters and comparators. The
instrument is capable of measuring all principle parameters
of a mains frequency network, from 15 to
70 Hz, and harmonics up to 3500 Hz.
The basic accuracy of the system is 0.01%. The
transfer error of the unit can be verified at any time
by using an external DC reference voltage.
Features
• Excellent price / performance ratio
• Universal unit for many applications
• One wide range input for each signal: Voltage:
30 V - 500 V
Current: 1 mA - 160 A
• High precision and long term stability
• Can be used with computer system
• Automatic range switching
• Analogue - digital data acquisition with 6 x ADCs
• Verification against D.C. reference voltage
• Error calculator for test of reference standard
meters
• Harmonics measurement up to 32nd
• Display of vector diagram or waveform
Download the Catalog
PRS 600.3
The PRS 600.3 is a combination of a three-phase Portable Reference
Standard of class 0.02% and an IEC 61000-4-30 Class A
compatible Power Quality Analyzer with 3 voltage and 3 current
channels. The device is equipped with two 8.4” colors TFT displays
based on touch screen operation. The Reference Standard is used
to test single and three phase meters, instrument transformers and
installations on site.
The Power Quality Analyzer is used as reference for PQ test systems,
to resolve disputes at contractual applications, for statistical
surveys, including EN 50160 reporting, and for online troubleshooting
of different kind of power quality problems.
The unit can be used with various types of clamp-on CTs and current
and voltage sensors. Therefore, it is possible to easily and accurately
test both CT/PT and direct connected meters.
WORKING STANDARD - Functions
• Meter testing of pulse outputs (LED/disc mark/S0) and registers
of active, reactive, apparent 1- or 3-phase, 3- or 4-wire
energy meters with 3 pulse inputs and 3 pulse outputs
• Measurement of electrical parameters (UI , PQS, f, PF) including vector diagram, harmonic analysis and wave form display.
• Instrument transformer testing (CT/PT burden, CT/PT ratio)
POWER QUALITY ANALYZER – Functions
in accordance with IEC 61000-4-30 Class A, IEC 62586-2, certified by ISO/IEC 17025 accredited laboratory NMi Certin B. V.
• Dips / Swells / Interruptions
• Harmonics / Interharmonics / Signal voltages
• Unbalance
• Under- and Overdeviation
• Rapid Voltage Changes RVC
• Flicker
• Transient capture 100s (26.7 kHz)
Download the Catalog
SRS 121.3
The SRS 121.3 three-phase, electronic reference standard in 0.05 accuracy class for use in meter test systems.
Key features of the SRS 121.3
• Three-phase reference standard
• Precision measurement unit for AC values in the frequency range of 45 to 70 Hz
• Simultaneous availability of the measured values over the RS 232 C serial line interface
• Test of two, three and four-wire meters
• Integrated measurement connection mode switching
• Easy operation due to the use of processor technology
• Operation verification with error indication
• Integrated RS 232C serial line interface for data transmission and programmed operation using an external computer
• Current and voltage ranges:
30 V to 520 V, 1 mA to 120 A
Download the Catalog
SRS 121.3/200A
The SRS 121.3 / 200 A three-phase, electronic reference standard in 0.05 accuracy class for use in meter test systems.
Key features of the SRS 121.3
• Three-phase reference standard
• Precision measurement unit for AC values in the frequency range of 45 to 70 Hz
• Simultaneous availability of the measured values over the RS 232 C serial line interface
• Test of two, three and four-wire meters
• Integrated measurement connection mode switching
• Easy operation due to the use of processor technology
• Operation verification with error indication
• Integrated RS 232C serial line interface for data transmission and programmed operation using an external computer
• Current and voltage ranges:
30 V to 520 V, 1 mA to 200 A
Download the Catalog
SRS 400.3
The SRS 400.3 three-phase, electronic reference standard in 0.02 accuracy class for use in meter test systems.
Key features of the SRS 400.3
• Three-phase reference standard
• Precision measurement unit for AC values in the frequency range of 45 to 70 Hz
• Simultaneous availability of the measured values over the RS 232 C serial line interface
• Test of two, three and four-wire meters
• Integrated measurement connection mode switching
• Easy operation due to the use of processor technology
• Operation verification with error indication
• Integrated RS 232C serial line interface for data transmission and programmed operation using an external computer
• Current and voltage ranges:
30 V to 520 V, 1 mA to 120 A
Download the Catalog
SRS 400.3/200 A
The SRS 400.3 / 200 A three-phase, electronic reference standard in 0.02 accuracy class for use in meter test systems.
Key features of the SRS 400.3
• Three-phase reference standard
• Precision measurement unit for AC values in the frequency range of 45 to 70 Hz
• Simultaneous availability of the measured values over the RS 232 C serial line interface
• Test of two, three and four-wire meters
• Integrated measurement connection mode switching
• Easy operation due to the use of processor technology
• Operation verification with error indication
• Integrated RS 232C serial line interface for data transmission and programmed operation using an external computer
• Current and voltage ranges:
30 V to 520 V, 1 mA to 200 A
Download the Catalog
SWS 1.3
The SWS 1.3 three-phase, electronic reference standard in 0.1 accuracy class for use in meter test systems
Key points of the SWS 1.3
• Three-phase working standard
• Precision measurement unit for AC values in the frequency range of 45 to 66 Hz
• Measurement of active, reactive and apparent power in 3 and 4 wire networks
• Impulse output for energy
• Current, voltage and Frequency measurement
• Control of output relays to control the energy dosage of register tests
• Error measurement
Download the Catalog